ThreeBond 3027D UV-curing resin |


ThreeBond 3027D is an acrylate-based one-part non-solvent UV-curing resin developed for ITO electrode molding. It cures in a short time under irradiation with UV light having a wavelength of 200 to 400 nm. The use of this resin will speed up the production lines and promote energy conservation.
Hereinafter, ThreeBond is abbreviated to TB. |


| · |
Curing in seconds to several tens of seconds under irradiation with UV light |
| · |
Low water absorption |
| · |
Repairable |
|


| · |
Molding of display panel ITO electrodes |


Properties


| Test item |
Unit |
Measurement |
Test method |
Remarks |
| Appearance |
- |
Light yellow to
lightclear white |
3TS-201-01 |
|
| Viscosity |
Pa·s |
2.0 |
3TS-201-02 |
25°C
No4 rotor 20 rpm |
| Specific gravity |
- |
1.01 |
3TS-213-02 |
25°C |
|
Flow curves (Rheometer)

 |

 |
 |
| |
Fig. 1 Viscosity curve and flow curve |
 |

 |
 |
| |
Fig. 2 Temperature-viscosity curve Shear Rate 1.0 (1/s) |
Characteristics of cured resin

| Table 2 Characteristics of cured resin |

| Test item |
Unit |
Test results |
Test method |
Remarks |
| Hardness |
- |
A80 |
3TS-215-01 |
25°C |
| Water absorption |
% |
0.2 |
3TS-215-03 |
|
| Moisture permeability |
g/m2·24h |
200-250 |
JIS K 7129 |
60°C × 95% RH |
| Thick film curability |
mm |
3.0 |
3TS-222-01 |
30kJ/m2 |
| Tensile shear bond strength |
MPa |
5.0 |
3TS-301-13 |
Glass/glass |
Ion
concentration |
Cl- |
ppm |
10 or less |
3TS-511-01 |
Extraction at
120°C for 48 hrs. |
| K+ |
5 or less |
| Na+ |
5 or less |
| Dielectric constant |
- |
2.5 |
JIS K 6911 |
1MHz |
| Dielectric loss tangent |
- |
0.03 |
1MHz |
| Dielectric breakdown voltage |
kV/mm |
18.4 |
|
| Volume resistivity |
Ω·m |
1 × 1011 or more |
|
| Surface resistivity |
Ω |
1 × 1015 or more |
|
|
 |
Irradiation conditions: 80-W/cm high-pressure mercury vapor lamp
Dominant wavelength: 365 nm
Irradiation distance: 15 cm
Integrated light intensity: 30 kJ/m2 or more |
Temperature characteristics of cured resin

| Table 3 Temperature characteristics of cured resin |

| Test item |
Unit |
Test results |
Test method |
Dynamic mechanical
analysis (DMA)
(1Hz) |
Storage modulus |
Pa |
1.6 × 109 (-40°C)
1.3 × 109 (-20°C)
8.5 × 108 (0°C)
4.4 × 108 (20°C)
4.3 × 107 (40°C)
2.7 × 107 (60°C)
2.5 × 107 (80°C) |
3TS-501-04 |
Loss modulus (E")
peak |
°C |
5.7 |
Loss tangent
(tan δ) peak |
°C |
34 |
| Linear expansion coefficient |
|
/°C |
123 × 10-6
272 × 10-6 |
3TS-501-05 |
| Glass transition point |
°C |
30 |
|
 |
Irradiation conditions: 80-W/cm high-pressure mercury vapor lamp
Dominant wavelength: 365 nm
Irradiation distance: 15 cm
Integrated light intensity: 30 kJ/m2 or more |
Usage

| · |
For the resin applying and curing procedures, consult with one of our sales engineers. |
Instructions for use

| 1) |
The curing speed varies depending on the type of light source and irradiation distance. Sufficiently check the curing speed prior to use. |
| 2) |
The resin in areas not exposed to UV light or in the shadows does not cure in principle. Before using it, sufficiently confirm whether the method of application and the purpose of use are appropriate. |
| 3) |
The resin generates some amount of gas during application and UV curing.
Forcibly ventilate the working area and UV irradiation area. If necessary, wear appropriate protective clothings, such as a mask, gloves (not permeable) and goggles. Use it in a place equipped with a local exhaust system. |
| 4) |
Do not inhale and drink it. It is harmful to the health. Do not inhale its vapor or drink it. If it is swallowed, get medical attention immediately. |
| 5) |
It is harmful to the health. Do not touch it directly or inhale its vapor.
Adhesion of the resin to the skin may cause inflammation. If it adheres to the skin, immediately wipe it away with cloth or paper, and wash the skin with soap and water. If it gets in the eyes, wash them with clean water for about 15 minutes, and get medical attention. |
| 6) |
If any abnormality is found in the body, stop using the resin, and get medical attention. People who have allergies or sensitive skin should avoid using it. |
| 7) |
Some materials may deteriorate if TB3027D is used. Ascertain in advance whether or not it affects the parts to be treated with it. If any problem occurs, do not use it. |
| 8) |
Do not pour TB3027D into other containers. Do not return the resin left unused to its container. |
| 9) |
To prevent deterioration or entry of foreign matter, store it with the cap fitted tightly after using. |
| 10) |
Use and store it out of reach of children. |
Storage

| · |
Store the product in a dry place at 10 to 25°C avoiding direct sunlight. |
| · |
If it is stored at a low temperature in a refrigerator or the like, the whole resin may harden or part of the resin may gel through crystallization. In this case, heat the resin to 30 to 40°C (for 1 to 2 hours), and stir it to return it to a uniform liquid state. |
Disposal

| · |
Have the product disposed of by a waste disposer that has special knowledge. |
| · |
It may generate toxic gas when burnt. Do not burn it. |
Safety precautions

 |
(It is not intended for household use) |
| Before using the product, approve the following conditions of sale. |
| 1) |
This technical information gives experimental values obtained by our specified test methods. We cannot thoroughly guarantee the correctness and perfectness of the data.
The user should determine whether the product is appropriate to the use and purpose before using it, and take all responsibilities for danger caused by it. The guarantee applies only to replacement of apparently defective product. |
| 2) |
We are not liable to injuries and damages caused by improper handling of this product. |
| 3) |
We do not take responsibility for any matter not mentioned herein unless otherwise mutually agreed in the contract. |
|
|
|
|