ThreeBond 1360E Anaerobic sealant |


ThreeBond 1360E is an anaerobic sealant that has high strength and excellent heat resistance. It does not cure in air, and it quickly reacts (cures by polymerizing) when it contacts metals and the air around it is expelled. It bonds and seals screws and jointed parts. |


| · |
Has high strength. |
| · |
Has high heat resistance. |
|


| · |
Bonding of screws and jointed parts that require high heat resistance. |


Properties

| Test items |
Units |
Properties |
Test method |
Remarks |
| Main component |
- |
(Meta) acrylic ester |
- |
|
| Appearance |
- |
Blue |
3TS-201-01 |
Eye observation |
| Viscosity |
mPa.s |
200 |
3TS-210-01 |
BL type viscometer, Rotor No.3, 60 RPM |
| Specific gravity |
- |
1.10 |
3TS-213-02 |
|
|
Characteristics(for bolts/nuts)

| Test items |
Units |
Values |
Test method |
Remarks |
| Adhesive strength after 2 hours (torque to break)* |
N.m |
25.8 |
3TS-306-01 |
Fe bolt/nut |
| N.m |
3.4 |
3TS-306-01 |
Zn-Cr bolt/nut |
| N.m |
5.6 |
3TS-306-01 |
SUS306 bolt/nut |
| N.m |
5.8 |
3TS-306-01 |
Ni-Cr bolt/nut |
| N.m |
21.0 |
3TS-306-01 |
Dacro bolt/nut |
| N.m |
14.2 |
3TS-306-01 |
Uni-chromate bolt/nut |
| N.m |
19.6 |
3TS-306-01 |
Al bolt/nut |
| N.m |
19.6 |
3TS-306-01 |
Black oxide finish bolt/nut |
| N.m |
40.4 |
3TS-306-01 |
Brass bolt/nut |
| Adhesive strength after 24 hours (torque to break)* |
N.m |
43.0 |
3TS-306-01 |
Fe bolt/nut |
| N.m |
9.6 |
3TS-306-01 |
Zn-Cr bolt/nut |
| N.m |
19.6 |
3TS-306-01 |
SUS306 bolt/nut |
| N.m |
24.6 |
3TS-306-01 |
Ni-Cr bolt/nut |
| N.m |
15.2 |
3TS-306-01 |
Dacro bolt/nut |
| N.m |
28.0 |
3TS-306-01 |
Uni-chromate bolt/nut |
| N.m |
Material breakage |
3TS-306-01 |
Al bolt/nut |
| N.m |
27.6 |
3TS-306-01 |
Black oxide finish bolt/nut |
| N.m |
Material breakage |
3TS-306-01 |
Brass bolt/nut |
| Set time * |
min |
4 |
3TS-220-03 |
Fe bolt/nut |
| min |
60 |
3TS-220-03 |
Zn-Cr bolt/nut |
|
 |
| * |
Test conditions: Apply ThreeBond 1360E to M10 P1.5 bolts/nuts of each material, and tighten them with 0N.m and bond, and let them cure at 25°C. Measure torque and set time once every hour. |
Characteristics(for joints)

| Test items |
Units |
Characteristics |
Test method |
Remarks |
| Adhesive strength after 1 hour |
MPa |
26.1 |
3TS-305-01 |
Fe |
| MPa |
10.3 |
3TS-305-01 |
SUS306 |
| MPa |
6.4 |
3TS-305-01 |
Al |
| MPa |
26.7 |
3TS-305-01 |
Fe (TB1390K)* |
| MPa |
25.3 |
3TS-305-01 |
Fe (TB1390E)* |
| MPa |
13.6 |
3TS-305-01 |
Fe (TB1390F)* |
| Adhesive strength after 24 hour |
MPa |
36.6 |
3TS-305-01 |
Fe |
| MPa |
28.6 |
3TS-305-01 |
SUS306 |
| MPa |
23.4 |
3TS-305-01 |
Al |
| MPa |
36.6 |
3TS-305-01 |
Fe (TB1390K)* |
| MPa |
33.4 |
3TS-305-01 |
Fe (TB1390E)* |
| MPa |
26.3 |
3TS-305-01 |
Fe (TB1390F)* |
| Set time |
sec |
240 |
3TS-220-03 |
Fe |
| sec |
15 |
3TS-220-03 |
Fe (TB1390K)* |
| sec |
60 |
3TS-220-03 |
Fe (TB1390E)* |
| sec |
5 |
3TS-220-03 |
Fe (TB1390F)* |
|
 |
| * |
Characteristic values when curing accelerators TB1390K, TB1390E, or TB1390F is added to Fe. |
Characteristics(thermal analysis)

| Test items |
Units |
Characteristics |
Test method |
Remarks |
| Glass transition point |
°C |
147 |
3TS-501-04 |
DMA method, 1Hz E” peak |
| °C |
166 |
3TS-501-04 |
DMA method, 1Hz tanδ peak |
|
Curing speed

|

 |
| |
Figure 1. Curing-speed curve of ThreeBond 1360E |
 |
| Test conditions: |
Apply ThreeBond 1360E to M10 P1.5 bolts and nuts of several materials, tighten them with 0N.m and bond, and let them cure at 25°C. Measure torque once every hour. |
Strength at high temperatures (for bolts/nuts)

|

 |
| |
Figure 2. Curve to show strength of ThreeBond 1360E at high temperatures |
 |
| Test conditions: |
Apply ThreeBond 1360E to Fe M10 P1.5 bolt and nut, tighten them with 0N.m and bond, and let them cure at 25°C for 48 hours. Leave them at each temperature for another 1 hour, and measure torque quickly. |
Strength at high temperatures (for joints)

|

 |
| |
Figure 3. Curve to show strength of ThreeBond 1360E at high temperatures |
 |
| Test conditions: |
Apply ThreeBond 1360E to Fe joint-test pieces, bond, and let them cure at 25°C for 48 hours. Leave them at each temperature for another 1 hour, and measure adhesive strength quickly. |
Dynamic mechanical analysis(DMA)

|

 |
| |
Figure 4. Curves of storage modulus (E') and loss modulus of ThreeBond 1360E (E”) |
 |
| Test conditions: |
Cure ThreeBond 1360E with TB1390E (primer), and leave them for 20 minutes at 150°C. Then perform DMA (speed of temperature raising: 3°C/min). |
How to use this sealant

| 1) |
Using a solvent, remove moisture, oil, and dirt from the area to which the sealant is to be applied. |
| 2) |
Apply an adequate quantity of the sealant and bond them firmly. |
| 3) |
If you have questions about the application and curing of this sealant, consult ThreeBond sales engineers. |
Cautions about using this sealant

| 1) |
Because this sealant is hazardous, don't touch it directly, and don't inhale its vapor. If it adheres to your skin, the skin may be irritated. Immediately remove it with cloth or paper, and clean the skin with soap. If any gets into your eye, clean the eye with water for about 15 minutes, and then consult a doctor. |
| 2) |
If you detect any bad symptom on your body when you use this sealant, stop using it, and consult a doctor. Persons who have allergy or have susceptible skin should not use this sealant. |
| 3) |
Because this sealant contains a hazardous component, it cannot be used for pipes that convey drinking water. Use this sealant only after confirming that the method and purpose of its use are appropriate. |
| 4) |
Don't move this sealant to other containers, and don't return any residue of applied sealant to the container. |
| 5) |
On some materials this sealant may have adverse effects, such as cracks, corrosion, or dissolving. Test the effect of the sealant on and around the areas of application, and refrain from using it if you find that it might cause a problem. |
| 6) |
Because this sealant cures, don't use metal nozzles for pouring it from its container. |
| 7) |
To prevent any change of the properties of the sealant, or the incorporation of foreign materials, recap the container after use. |
| 8) |
If this sealant is cured at high temperature, it will lose the fluidity that remains when it is cured at room temperature. However, you can retain fluidity by curing it at a somewhat raised temperature. Before applying the sealant, confirm the conditions under which it will be cured. |
| 9) |
For detailed information, refer to the Material Safety Data Sheet (MSDS). |
How to store the sealant

| 1) |
Store this sealant at -5°C to 25°C under no sunlight. |
| 2) |
Store and use it out of the reach of infants and children. |
How to discard the sealant

| 1) |
Don't incinerate the sealant. To do so may generate poisonous gases. |
| 2) |
If you need to discard this sealant, have it discarded by a dealer who has specialized knowledge. |
Legal regulations

| |
Fire protection law: |
Flammable, Number 4 category Number 3 petroleum, Acrylate adhesive, Hazard class 3 |
Cautions

 |
(Don't use this sealant at home.) |
| Use this sealant only after accepting the following sales conditions: |
| 1) |
The technical information we present, such as written data, consists of experimental values resulting from tests performed in accordance with our specifications, and we cannot absolutely guarantee its accuracy and integrity. Customers who use this sealant are expected to judge for themselves, before use, whether this product is appropriate for their use, and to have the full responsibility and risks for the use of the product. Our guarantee extends only to the replacement of any products found to be defective. |
| 2) |
ThreeBond cannot take any responsibility for personal injury or property damage that may result from improper use of this product. |
| 3) |
ThreeBond cannot take any responsibility for occurrences not specified in this home page, except as specified in a written contract with a customer. |
|
|
|