Product Information

ThreeBond 1360F Anaerobic sealant



Overview

ThreeBond 1360F is an anaerobic sealant that has high strength and excellent heat resistance. It does not cure in air, and it quickly reacts (cures by polymerizing) when it contacts metals and the air around it is expelled. It bonds and seals screws and jointed parts.

Features

· Has high strength.
· Has high heat resistance.

Uses

· Bonding of screws and jointed parts that require high heat resistance.

Properties

Properties

Table 1. Properties of ThreeBond 1360F

Test items Units Properties Test method Remarks
Main component - (Meta) acrylic ester -  
Appearance - Green 3TS-201-01 Eye observation
Viscosity mPa.s 500 3TS-210-01 BL type viscometer, Rotor No.3, 60rpm
Specific gravity - 1.10 3TS-213-02  

Characteristics

Table 2. Characteristics of ThreeBond 1360F (for bolts/nuts)

Test items Units Values Test method Remarks
Adhesive strength after 2 hours
(torque to break)*
N.m 25.2 3TS-306-01 Fe bolt/nut
N.m 3.4 3TS-306-01 Zn-Cr bolt/nut
N.m 5.8 3TS-306-01 SUS306 bolt/nut
N.m 5.2 3TS-306-01 Ni-Cr bolt/nut
N.m 21.5 3TS-306-01 Dacro bolt/nut
N.m 14.6 3TS-306-01 Uni-chromate bolt/nut
N.m 19.4 3TS-306-01 Al bolt/nut
N.m 18.2 3TS-306-01 Black oxide finish bolt/nut
N.m 42.7 3TS-306-01 Brass bolt/nut
Adhesive strength after 24 hours
(torque to break)*
N.m 41.6 3TS-306-01 Fe bolt/nut
N.m 9.2 3TS-306-01 Zn-Cr bolt/nut
N.m 17.6 3TS-306-01 SUS306 bolt/nut
N.m 22.6 3TS-306-01 Ni-Cr bolt/nut
N.m 16.2 3TS-306-01 Dacro bolt/nut
N.m 30.2 3TS-306-01 Uni-chromate bolt/nut
N.m Material breakage 3TS-306-01 Al bolt/nut
N.m 31.4 3TS-306-01 Black oxide finish bolt/nut
N.m Material breakage 3TS-306-01 Brass bolt/nut
Set time* min 4 3TS-220-03 Fe bolt/nut
min 60 3TS-220-03 Zn-Cr bolt/nut
* Test conditions: Apply ThreeBond 1360F to M10 P1.5 bolts/nuts of each material, and tighten them with 0N.m and bond, and let them cure at 25°C. Measure torque after 2 and 24 hours and measure set time.

Table 3. Characteristics of ThreeBond 1360F (for joints)

Test items Units Characteristics Test method Remarks
Adhesive strength after 1 hour MPa 26.5 3TS-305-01 Fe
MPa 10.0 3TS-305-01 SUS306
MPa 5.8 3TS-305-01 Al
MPa 27.3 3TS-305-01 Fe (ThreeBond 1390K)*
MPa 23.4 3TS-305-01 Fe (ThreeBond 1390E)*
MPa 15.1 3TS-305-01 Fe (ThreeBond 1390F)*
Adhesive strength after 24 hours MPa 36.6 3TS-305-01 Fe
MPa 28.6 3TS-305-01 SUS306
MPa 23.4 3TS-305-01 Al
MPa 36.2 3TS-305-01 Fe (ThreeBond 1390K)*
MPa 34.8 3TS-305-01 Fe (ThreeBond 1390E)*
MPa 29.0 3TS-305-01 Fe (ThreeBond 1390F)*
Set time s 240 3TS-220-03 Fe
s 15 3TS-220-03 Fe (ThreeBond 1390K)*
s 60 3TS-220-03 Fe (ThreeBond 1390E)*
s 5 3TS-220-03 Fe (ThreeBond 1390F)*
* Characteristic values when curing accelerator ThreeBond 1390K, ThreeBond 1390E, or ThreeBond 1390F is applied to Fe.

Table 4. Other characteristics of ThreeBond 1360F

Test items Units Characteristics Test method Remarks
Glass transition point °C 145 3TS-501-04 DMA method, 1Hz E” peak
°C 165 3TS-501-04 DMA method, 1Hz tanδ peak
Line extension rate ×10-6 62.9 3TS-501-05 TMA method 20-30°C
×10-6 133.3 3TS-501-05 TMA method 150-160°C
Curing contraction rate % 8.7 3TS-228-01  

Curing speed


Curing speed curve of ThreeBond 1360F
  Figure 1. Curing speed curve of ThreeBond 1360F
Test conditions:  Apply ThreeBond 1360F to Fe M10 P1.5 bolts and nuts, tighten them with 0N.m and bond, and let them cure at 25°C. Measure torque after specified hours.

Strength at high temperatures (for bolts/nuts)


Curve to show strength of ThreeBond 1360F at high temperatures
  Figure 2. Curve to show strength of ThreeBond 1360F at high temperatures
Test conditions: Apply ThreeBond 1360F to Fe M10 P1.5 bolt and nut, tighten them with 0N.m and bond, and let them cure at 25°C for 48 hours. Leave them at each temperature for another 1 hour, and measure torque.

Strength at high temperatures (for joints)


Curve to show strength of ThreeBond 1360F at high temperatures
  Figure 3. Curve to show strength of ThreeBond 1360F at high temperatures
Test conditions: Apply ThreeBond 1360F to Fe pieces for joint test, tighten them and bond, and let them cure at 25°C for 48 hours. Leave them at each temperature for another 1 hour, and measure adhesive strength.

Dynamic mechanical analysis (DMA)


Curves of storage modulus (E') and loss modulus (E”) of ThreeBond 1360F
  Figure 4. Curves of storage modulus (E') and loss modulus (E”) of ThreeBond 1360F
Test conditions: Cure ThreeBond 1360F with ThreeBond 1390E (primer), and leave them for 20 minutes at 150°C. Then perform DMA (speed of temperature raising: 3°C /min).


How to use this sealant

1) Using a solvent, remove moisture, oil, and dirt from the area to which the sealant is to be applied.
2) Apply an adequate quantity of the sealant and bond them firmly.
3) If you have questions about the applying and curing method of this sealant, consult ThreeBond sales engineers.

Cautions about using this sealant

1) Because this sealant is hazardous, don't touch it directly, and don't inhale its vapor. If it adheres to your skin, the skin may be irritated. Immediately remove it with cloth or paper, and clean the skin with soap. If any gets into your eye, clean the eye with water for about 15 minutes, and then consult a doctor.
2) If you detect any bad symptom on your body when you use this sealant, stop using it, and consult a doctor. Persons who have allergy or have susceptible skin should not use this sealant.
3) Because this sealant contains a hazardous component, it cannot be used for pipes that convey drinking water. To prevent the content of this sealant from melting into the drinking water, confirm that the method and purpose of its use are appropriate.
4) Don't move this sealant to other containers, and don't return any residue of applied sealant to the container.
5) On some materials this sealant may have adverse effects, such as cracks, corrosion, or dissolving. Test the effect of the sealant on and around the areas of application, and refrain from using it if you find that it might cause a problem.
6) Because this sealant cures, don't use metal nozzles for pouring it from its container.
7) To prevent any change of the properties of the sealant, or the incorporation of foreign materials, recap the container after use.
8) If this sealant cures at high temperature, it may lose the fluidity that remains when it cures at room temperature. However, you can retain fluidity when it cures at a somewhat raised temperature. Before applying the sealant, confirm the conditions under which it cures.
9) For detailed information, refer to the Material Safety Data Sheet (MSDS).

How to store the sealant

1) Store this sealant at -5°C to 25°C under no sunlight.
2) Store and use it out of the reach of infants and children.

How to discard the sealant

1) Don't incinerate the sealant. If you do so, it may generate poisonous gases.
2) If you need to discard this sealant, have it discarded by a dealer who has specialized knowledge.

Legal regulations

    Fire protection law: Flammable material, Number 4 category Number 3 petroleum, Acrylate adhesive, Hazard class 3

Cautions

Industrial use (Don't use this sealant at home.)

Use this sealant only after accepting the following sales conditions:
1) The technical information we present, such as written data, consists of experimental values resulting from tests performed in accordance with our specifications, and we cannot absolutely guarantee its accuracy and integrity. Customers who use this sealant are expected to judge by themselves, before use, whether this product is appropriate for their use, and to have the full responsibility and risks for the use of the product. Our guarantee extends only to the replacement of any products found to be defective.
2) ThreeBond cannot take any responsibility for personal injury or property damage that may result from improper use of this product.
3) ThreeBond cannot take any responsibility for occurrences not specified in this home page, except as specified in a written contract with a customer.
Back to top
Policy for keeing privacyLink to the related sites Copyright  2006 ThreeBond Co., Ltd.All rights reserved.